Measurement Module Terms
Last updated: September 2026
1. When These Terms Apply
These Measurement Module Terms apply only if you enable, purchase, or use a feature of the Kronus Instruments platform that captures, imports, computes, or reports instrument readings — including corrosion, moisture, and any other sensor-based or quantitative measurement feature we offer now or later (each a "Measurement Module"). They are part of, and use the definitions in, the Terms of Service between you and Kronus Instruments Inc. ("Kronus"), and they control over the Terms of Service on matters concerning Measurement Modules. If you never use a Measurement Module, these terms do not affect you.
2. What Measurement Modules Do and Do Not Do
2.1 Measurement Modules record readings, apply calculations and settings you select, and present the results alongside your photos, locations, and notes. They are tools for collecting and organizing data.
2.2 Measurement Modules do not diagnose, certify, grade, or approve anything. In particular, they do not determine structural adequacy, remaining service life, the presence or absence of active corrosion, mold, leaks, or hidden damage, habitability, code compliance, or the cause or cost of any condition. Any such conclusion is yours, made on your own professional judgment.
2.3 Kronus does not provide engineering, inspection, or other professional services and does not supervise or review your work. Color scales, thresholds, flags, and summaries shown by a Measurement Module are display aids based on general assumptions or on values you configure; they are not pass/fail determinations.
3. Your Responsibilities
You are solely responsible for: (a) ensuring each operator is trained and qualified for the method being used and holds any license or certification your jurisdiction or client requires; (b) choosing a test method that is appropriate for the material, structure, and purpose, and following the standards, specifications, and manufacturer instructions that apply to it; (c) verifying and calibrating instruments as required by the Documentation and those standards, and before relying on results; (d) selecting the correct material, species, mix, or other settings, and entering accurate project information; (e) surface preparation, sensor or probe placement, contact quality, the number and spacing of readings, and recording the site conditions that affect interpretation; (f) confirming significant or unexpected results by repeat readings and, where a decision has meaningful consequences, by an independent or alternative method; (g) reviewing every Report for accuracy and completeness before you issue it; and (h) keeping your own records for as long as your profession, clients, or the law require.
4. Accuracy and Known Limitations
4.1 All readings and derived values are estimates. Field results can differ materially from the accuracy figures in the Documentation, which describe typical performance under reference conditions.
4.2 Readings can be affected by, among other things: temperature and humidity; surface moisture and condensation; salts, chlorides, and other contaminants; coatings, sealers, and surface treatments; concrete cover depth, carbonation, and resistivity; embedded or nearby metal; material density, composition, and variability; electrical continuity and connection quality; stray currents and electrical interference; instrument condition and battery level; and operator technique. False-positive and false-negative indications are possible.
4.3 Values that a Measurement Module derives from readings — such as converted moisture content, corrosion likelihood or rate indications, trends, maps, and interpolations between points — depend on assumptions, reference tables, and the inputs you provide, and may not hold for your specific material or conditions. Conditions between, behind, or beyond the points actually measured are not known.
4.4 We may change calculations, reference data, and default thresholds as we improve the Service. We will describe material changes in release notes. You are responsible for checking whether a change affects how you interpret new or historical results.
5. Third-Party Instruments and Imported Data
If a Measurement Module accepts readings from instruments not made by Kronus, or data that is typed in or imported, Kronus is not responsible for the accuracy of that data, for the instrument's performance, or for changes the instrument's maker makes that affect compatibility.
6. Reports and Your Clients
You are the author of, and solely responsible for, every Report that includes Measurement Data. You will not state or imply that Kronus tested, certified, reviewed, or stands behind any result or finding. You are responsible for including in your Reports the scope, method, limitations, and disclaimers appropriate to your profession and your agreement with your client. As stated in the Terms of Service, recipients of your Reports have no rights or claims against Kronus.
7. High-Risk Use
Measurement Modules are not fault-tolerant and must not be used as the sole basis for any decision where an incorrect or missing reading could lead to death, personal injury, or severe property or environmental damage, including decisions about structural loading, shoring or demolition, occupancy, or the safety of energized or pressurized systems. Those decisions require a qualified professional using appropriate independent verification.
8. Indemnification
In addition to your obligations under the Terms of Service, you will defend Kronus and its affiliates, officers, employees, and agents against any third-party claim, and pay the resulting damages, settlements, and reasonable legal fees, arising from bodily injury, death, property damage, or economic loss alleged to result from: (a) your or anyone else's reliance on Measurement Data or on a Report you issued; (b) your failure to meet any responsibility in Section 3; (c) the professional services, opinions, or recommendations you provide; or (d) use of a Measurement Module contrary to Section 7. This obligation does not apply to the extent a claim is finally determined to have been caused by Kronus's gross negligence or willful misconduct. The procedures in the indemnification section of the Terms of Service apply.
9. Disclaimer and Liability
MEASUREMENT MODULES, MEASUREMENT DATA, AND ALL DERIVED VALUES, INDICATIONS, AND VISUALIZATIONS ARE PROVIDED "AS IS." TO THE FULLEST EXTENT PERMITTED BY LAW, KRONUS DISCLAIMS ALL WARRANTIES REGARDING THEIR ACCURACY, RELIABILITY, COMPLETENESS, OR FITNESS FOR ANY PARTICULAR PURPOSE OR DECISION. YOU ASSUME THE ENTIRE RISK OF RELYING ON THEM. The disclaimers, exclusions, and limits of liability in the Terms of Service apply to Measurement Modules; the limited warranty for Hardware is stated only in the Hardware Terms of Sale.
10. Measurement Data and Product Improvement
Measurement Data you collect is Customer Data and belongs to you. As described in the Terms of Service, we may use aggregated or de-identified Measurement Data, which does not identify you, your clients, or a specific property, to validate and improve our instruments, calculations, and models.
11. Contact
Questions about these terms? Contact us at info@kronusinstruments.com.
